# API 5L seamless pipe RFQ checklist: PSL, CVN, MTC and delivery

Published: 2026-11-20

Short answer: a usable API 5L seamless pipe RFQ states the API 5L edition,
PSL1 or PSL2, grade and delivery condition, OD, wall thickness or weight,
length, quantity, impact-test requirement, inspection, MTC, coating and
destination port.

## Minimum RFQ data

| RFQ field | What to state | Why it matters |
|---|---|---|
| Standard | API 5L and applicable edition or project amendment | Defines product and acceptance basis |
| PSL | PSL1 or PSL2, plus project supplement | Controls chemistry, tensile and testing |
| Grade | B/X42 through X80 or another specified grade | Sets strength range and material route |
| Size and length | OD, wall or weight, fixed/random length and ends | Drives production and dimensional checks |
| Quantity | Pieces, metres or metric tonnes | Defines the commercial quantity |
| CVN | Temperature, energy or lateral expansion, specimen and frequency | Makes toughness requirements checkable |
| Inspection | Dimension, visual, UT, hydrostatic, hardness, PMI, third-party | Changes price, lead time and records |
| Documents | EN 10204 3.1 MTC, NDT and pressure records, packing list | Makes release auditable |
| Coating | Bare, varnish, FBE or other approved system | Changes processing and protection |
| Delivery | Destination port, Incoterm and required date | Connects product and logistics |

## PSL1 and PSL2

Do not infer PSL from the steel grade. The governing design, purchase
specification and project requirements determine whether PSL1 or PSL2 is
required. If CVN, NDT or third-party release is required, state the conditions
instead of relying on the PSL label alone.

## CVN requirement

State:

- test temperature in °C;
- absorbed energy in joules or lateral-expansion criterion;
- specimen size and orientation;
- test frequency;
- source of the requirement, such as API 5L or the project specification.

## MTC and inspection

An EN 10204 3.1 MTC should be checked against the purchase order, standard,
grade, PSL, dimensions, heat number, chemical and mechanical results and issuer.
UT, hydrostatic testing, hardness, PMI and third-party release must each be tied
to the required method, coverage, acceptance basis and report.

An EN 10204 3.1 MTC is not the same as an SGS, BV, TÜV or buyer-nominated
inspection release.

## Example RFQ structure

- Product: API 5L seamless line pipe, PSL2, approved grade.
- Size: state OD, wall or weight, length and end finish.
- Quantity: metric tonnes, metres or pieces.
- Toughness: CVN temperature, acceptance and frequency.
- Inspection: dimensional, visual, UT, hydrostatic, hardness, PMI and witness points.
- Documents: EN 10204 3.1 MTC and specified test records.
- Coating: bare, varnish, FBE or another approved system.
- Delivery: destination port, Incoterm and required date.

## Related guides

- [API 5L / API 5CT technical data](api-5l-api-5ct-technical-data.html)
- [API 5L X60](api-5l-x60-psl2-seamless-pipe.html)
- [API 5L X65](api-5l-x65-psl2-seamless-pipe.html)
- [EN 10204 3.1 verification](en-10204-mtc-verification-checklist.html)
- [Quality evidence](quality-evidence.html)
- [Procurement blog](blog.html)

## FAQ

### What should an API 5L seamless pipe RFQ include?

State the API 5L edition, product specification level, grade and delivery
condition, outside diameter, wall thickness or weight, length, end finish,
quantity, coating, impact-test requirements, inspection, documents and
destination port.

### Is API 5L PSL2 always required?

No. PSL1 or PSL2 is selected by the governing design, purchase specification
and project requirements. PSL2 introduces additional chemistry, tensile and
testing controls, so the required PSL must be stated rather than inferred from
the steel grade.

### Which documents should accompany an API 5L pipe order?

A typical document scope includes an EN 10204 3.1 mill test certificate
traceable to the pipe heat number, dimensional and visual records, NDT and
hydrostatic records where specified, and the packing list. Third-party
inspection is a separate agreed service.

### Can X60 be substituted for X65?

Not without engineering approval. API 5L grades have different strength ranges,
and the design may also control wall thickness, toughness, welding and pressure
capacity. A grade substitution changes the technical basis and must be approved
before quotation or production.

### Are API 5L and API 5CT pipe interchangeable?

No. API 5L covers line pipe for transporting oil, gas or water. API 5CT covers
casing and tubing used in a well. Product form, grade, dimensions, connections,
service and inspection requirements differ and require engineering approval
before any substitution.

## Contact

- [Request a quotation](index.html#contact)